Orion's Office Pro 1500 line interactive UPS rated at 1500VA/1200 Watts. Compact tower design, features include automatic voltage regulation, 6 UPS and surge protected receptacles, and data/modem line protection for your small/home office computer and telephone equipment.
- 1500VA/1200 watt capacity provides 5 minutes of battery runtime at full load
- 120V input/output with 6 NEMA 5-15R output receptacles
- LAN and phone line protection for communications equipment, includes USB port and cables
- Software is included to monitor UPS and gracefully shutdown or restart UPS connected systems during an extended power failure
- 2 year limited warranty with product registration, $10,000 load protection guarantee
- Dim. 6.2"H x 5.8"W x 14.2"D / Weight 33 lbs
| Input |
| Voltage Window |
84-147VAC |
| Frequency |
60 Hz |
| Output |
| Voltage AC Mode |
1st boost: 15%(Input -10~-20%); 2nd boost: 30%(Input -20~-30%); Buck: 15%(Input +10~22.5%) |
| Voltage Inverter Mode |
115 +/- 10% |
| Frequency |
50/60Hz +/- 1 Hz |
| Capacity |
1500VA/900 watts |
| Waveform |
Simulated Sine Wave |
| Transfer Time |
4ms typical |
| Backup Time |
5-30 minutes typical for PC load |
| DC Start |
Yes |
| Battery |
| Type |
Sealed Lead Acid Maintenance Free |
| Recharge Time |
8 hours to 90% |
| Display |
| LED |
4 LEDs for Line, Backup, Fault, and Overload |
| Self-Diagnostics |
Upon Power On and Software Control |
| Protection |
| Overload - AC Mode |
>105% audible alarm beeps continuously |
| Overload - Inverter Mode |
>105% to < 109% audible alarm beeps continuously; >110% UPS shuts down immediately then alarms 5 seconds |
| Short Circuit - AC Mode |
Input fuse and electronic circuit |
| Short Circuit - Inverter Mode |
Electronic circuit |
| Alarms |
| Audible and Visual |
Line Failure, Battery Low, Overload, and Fault conditions |
| Physical |
| Dimensions |
14.2"H x 5.8"W x 6.2"D |
| Outlets |
(6) NEMA 5-15R Backup and Surge Protected |
| Net Weight |
32.5 lbs. |
| Environment |
| Operating Temperature |
32 to 104 F |
| Temperature Warning |
Battery design life is based on a temperature of 77 F. Ambient temperature above this range will impact battery life. |
| Humidity |
95% RH maximum, non-condensing |
| Computer Interface |
| Interface Type |
USB |
| Compatible Platforms |
Windows 95/98/NT/XP/Vista/7, Novell Netware, Linux |
| Safety Conformance |
| Quality Assurance |
ISO9001 Certified |
| Safety Standard |
EN62040-1-1 |
| EMC Standard |
EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A |
| Marks |
UL, cUL |
Part #: UPS-OP1500U Shipping Weight: 33.0000
Length: 14.2000 Width: 5.8000 Depth: 6.2000